For a Ø16 mm nominal diameter, ISO 286 H7/p6 produces a interference fit with hole limits of 16.000 – 16.018 mm (0 µm / +18 µm) and shaft limits of 16.018 – 16.029 mm (+18 µm / +29 µm).
ISO 286 Ø16 mm H7/p6 Fit Limits (Interference Fit)
ISO 286-1ISO 286-2
Primary Engineering Specifications
- Nominal Diameter
- Ø16 mm
- Fit Classification
- Interference Fit
- Hole Limits (H7)
- 16.000 – 16.018 mm
- Hole Deviations (EI / ES)
- 0 µm / +18 µm
- Shaft Limits (p6)
- 16.018 – 16.029 mm
- Shaft Deviations (ei / es)
- +18 µm / +29 µm
Clearance / Interference Summary
- Maximum Clearance / Min Interference
- 0.000 mm (0 µm)
- Minimum Clearance / Max Interference
- -0.029 mm (-29 µm)
- Hole Tolerance Band (IT7)
- 18 µm
- Shaft Tolerance Band (IT6)
- 11 µm
Design & Manufacturing Note
Light interference press fit capable of transmitting moderate torque without keys in steel hubs.
Frequently Asked Questions
What are the exact hole and shaft sizes for Ø16 H7/p6?
According to ISO 286-2, the H7 hole must measure 16.000 – 16.018 mm and the p6 shaft must measure 16.018 – 16.029 mm.
Is Ø16 H7/p6 a clearance, transition, or interference fit?
Ø16 H7/p6 is classified as a Interference Fit with extreme fit values from -0.029 mm to 0.000 mm.