MECHSOLVER

ISO 286 Ø16 mm H7/h6 Fit Limits (Clearance Fit)

ISO 286-1ISO 286-2

For a Ø16 mm nominal diameter, ISO 286 H7/h6 produces a clearance fit with hole limits of 16.000 – 16.018 mm (0 µm / +18 µm) and shaft limits of 15.989 – 16.000 mm (-11 µm / 0 µm).

Primary Engineering Specifications

Nominal Diameter
Ø16 mm
Fit Classification
Clearance Fit
Hole Limits (H7)
16.000 – 16.018 mm
Hole Deviations (EI / ES)
0 µm / +18 µm
Shaft Limits (h6)
15.989 – 16.000 mm
Shaft Deviations (ei / es)
-11 µm / 0 µm

Clearance / Interference Summary

Maximum Clearance / Min Interference
0.029 mm (+29 µm)
Minimum Clearance / Max Interference
0.000 mm (0 µm)
Hole Tolerance Band (IT7)
18 µm
Shaft Tolerance Band (IT6)
11 µm

Design & Manufacturing Note

Close location clearance fit with zero minimum clearance for hand-assembled spigots and locating pins.

Frequently Asked Questions

What are the exact hole and shaft sizes for Ø16 H7/h6?

According to ISO 286-2, the H7 hole must measure 16.000 – 16.018 mm and the h6 shaft must measure 15.989 – 16.000 mm.

Is Ø16 H7/h6 a clearance, transition, or interference fit?

Ø16 H7/h6 is classified as a Clearance Fit with extreme fit values from 0.000 mm to 0.029 mm.