MECHSOLVER

ISO 286 Ø50 mm H7/p6 Fit Limits (Interference Fit)

ISO 286-1ISO 286-2

For a Ø50 mm nominal diameter, ISO 286 H7/p6 produces a interference fit with hole limits of 50.000 – 50.025 mm (0 µm / +25 µm) and shaft limits of 50.026 – 50.042 mm (+26 µm / +42 µm).

Primary Engineering Specifications

Nominal Diameter
Ø50 mm
Fit Classification
Interference Fit
Hole Limits (H7)
50.000 – 50.025 mm
Hole Deviations (EI / ES)
0 µm / +25 µm
Shaft Limits (p6)
50.026 – 50.042 mm
Shaft Deviations (ei / es)
+26 µm / +42 µm

Clearance / Interference Summary

Maximum Clearance / Min Interference
-0.001 mm (-1 µm)
Minimum Clearance / Max Interference
-0.042 mm (-42 µm)
Hole Tolerance Band (IT7)
25 µm
Shaft Tolerance Band (IT6)
16 µm

Design & Manufacturing Note

Light interference press fit capable of transmitting moderate torque without keys in steel hubs.

Frequently Asked Questions

What are the exact hole and shaft sizes for Ø50 H7/p6?

According to ISO 286-2, the H7 hole must measure 50.000 – 50.025 mm and the p6 shaft must measure 50.026 – 50.042 mm.

Is Ø50 H7/p6 a clearance, transition, or interference fit?

Ø50 H7/p6 is classified as a Interference Fit with extreme fit values from -0.042 mm to -0.001 mm.