For a Ø35 mm nominal diameter, ISO 286 H7/p6 produces a interference fit with hole limits of 35.000 – 35.025 mm (0 µm / +25 µm) and shaft limits of 35.026 – 35.042 mm (+26 µm / +42 µm).
ISO 286 Ø35 mm H7/p6 Fit Limits (Interference Fit)
ISO 286-1ISO 286-2
Primary Engineering Specifications
- Nominal Diameter
- Ø35 mm
- Fit Classification
- Interference Fit
- Hole Limits (H7)
- 35.000 – 35.025 mm
- Hole Deviations (EI / ES)
- 0 µm / +25 µm
- Shaft Limits (p6)
- 35.026 – 35.042 mm
- Shaft Deviations (ei / es)
- +26 µm / +42 µm
Clearance / Interference Summary
- Maximum Clearance / Min Interference
- -0.001 mm (-1 µm)
- Minimum Clearance / Max Interference
- -0.042 mm (-42 µm)
- Hole Tolerance Band (IT7)
- 25 µm
- Shaft Tolerance Band (IT6)
- 16 µm
Design & Manufacturing Note
Light interference press fit capable of transmitting moderate torque without keys in steel hubs.
Frequently Asked Questions
What are the exact hole and shaft sizes for Ø35 H7/p6?
According to ISO 286-2, the H7 hole must measure 35.000 – 35.025 mm and the p6 shaft must measure 35.026 – 35.042 mm.
Is Ø35 H7/p6 a clearance, transition, or interference fit?
Ø35 H7/p6 is classified as a Interference Fit with extreme fit values from -0.042 mm to -0.001 mm.