For a Ø100 mm nominal diameter, ISO 286 H7/p6 produces a interference fit with hole limits of 100.000 – 100.035 mm (0 µm / +35 µm) and shaft limits of 100.037 – 100.059 mm (+37 µm / +59 µm).
ISO 286 Ø100 mm H7/p6 Fit Limits (Interference Fit)
ISO 286-1ISO 286-2
Primary Engineering Specifications
- Nominal Diameter
- Ø100 mm
- Fit Classification
- Interference Fit
- Hole Limits (H7)
- 100.000 – 100.035 mm
- Hole Deviations (EI / ES)
- 0 µm / +35 µm
- Shaft Limits (p6)
- 100.037 – 100.059 mm
- Shaft Deviations (ei / es)
- +37 µm / +59 µm
Clearance / Interference Summary
- Maximum Clearance / Min Interference
- -0.002 mm (-2 µm)
- Minimum Clearance / Max Interference
- -0.059 mm (-59 µm)
- Hole Tolerance Band (IT7)
- 35 µm
- Shaft Tolerance Band (IT6)
- 22 µm
Design & Manufacturing Note
Light interference press fit capable of transmitting moderate torque without keys in steel hubs.
Frequently Asked Questions
What are the exact hole and shaft sizes for Ø100 H7/p6?
According to ISO 286-2, the H7 hole must measure 100.000 – 100.035 mm and the p6 shaft must measure 100.037 – 100.059 mm.
Is Ø100 H7/p6 a clearance, transition, or interference fit?
Ø100 H7/p6 is classified as a Interference Fit with extreme fit values from -0.059 mm to -0.002 mm.