For a Ø50 mm nominal diameter, ISO 286 H7/n6 produces a transition fit with hole limits of 50.000 – 50.025 mm (0 µm / +25 µm) and shaft limits of 50.017 – 50.033 mm (+17 µm / +33 µm).
ISO 286 Ø50 mm H7/n6 Fit Limits (Transition Fit)
ISO 286-1ISO 286-2
Primary Engineering Specifications
- Nominal Diameter
- Ø50 mm
- Fit Classification
- Transition Fit
- Hole Limits (H7)
- 50.000 – 50.025 mm
- Hole Deviations (EI / ES)
- 0 µm / +25 µm
- Shaft Limits (n6)
- 50.017 – 50.033 mm
- Shaft Deviations (ei / es)
- +17 µm / +33 µm
Clearance / Interference Summary
- Maximum Clearance / Min Interference
- 0.008 mm (+8 µm)
- Minimum Clearance / Max Interference
- -0.033 mm (-33 µm)
- Hole Tolerance Band (IT7)
- 25 µm
- Shaft Tolerance Band (IT6)
- 16 µm
Design & Manufacturing Note
Tight transition/light press fit for heavily loaded bearings and semi-permanent hub assemblies.
Frequently Asked Questions
What are the exact hole and shaft sizes for Ø50 H7/n6?
According to ISO 286-2, the H7 hole must measure 50.000 – 50.025 mm and the n6 shaft must measure 50.017 – 50.033 mm.
Is Ø50 H7/n6 a clearance, transition, or interference fit?
Ø50 H7/n6 is classified as a Transition Fit with extreme fit values from -0.033 mm to 0.008 mm.